| Title: | Calibration of an orientation sensor for freehand 3D ultrasound and its use in a hybrid acquisition system |
| Authors: | Housden, R James Treece, Graham M Gee, Andrew H Prager, Richard W |
| Issue Date: | 24-Jan-2008 |
| Citation: | BioMedical Engineering OnLine 2008, 7:5 |
| Abstract: | Abstract Background Freehand 3D ultrasound is a powerful imaging modality with many potential applications. However, its reliance on add-on position sensors, which can be expensive, obtrusive and difficult to calibrate, is a major drawback. Alternatively, freehand 3D ultrasound can be acquired without a position sensor using image-based techniques. Sensorless reconstructions exhibit good fine scale detail but are prone to tracking drift, resulting in large scale geometrical distortions. Method We investigate an alternative position sensor, the Xsens MT9-B, which is relatively unobtrusive but measures orientation only. We describe a straightforward approach to calibrating the sensor, and we measure the calibration precision (by repeated calibrations) and the orientation accuracy (using independent orientation measurements). We introduce algorithms that allow the MT9-B potentially to correct both linear and angular drift in sensorless reconstructions. Results The MT9-B can be calibrated to a precision of around 1°. Reconstruction accuracy is also around 1°. The MT9-B was able to eliminate angular drift in sensorless reconstructions, though it had little impact on linear drift. In comparison, six degree-of-freedom drift correction was shown to produce excellent reconstructions. Conclusion Gold standard freehand 3D ultrasound acquisition requires the synthesis of image-based techniques, for good fine scale detail, and position sensors, for good large scale geometrical accuracy. A hybrid system incorporating the MT9-B offers an attractive compromise between quality and ease of use. The position sensor is unobtrusive and the system is capable of faithful acquisition, with the one exception of linear drift in the elevational direction. |
| Description: | RIGHTS : This article is licensed under the BioMed Central licence at http://www.biomedcentral.com/about/license which is similar to the 'Creative Commons Attribution Licence'. In brief you may : copy, distribute, and display the work; make derivative works; or make commercial use of the work - under the following conditions: the original author must be given credit; for any reuse or distribution, it must be made clear to others what the license terms of this work are. |
| URI: | http://www.dspace.cam.ac.uk/handle/1810/237659 http://dx.doi.org/10.1186/1475-925X-7-5 |
| Appears in Collections: | Scholarly works - Engineering |
Files in This Item:
|
| Additional resources for this item |
|---|
| search for alternative versions in eresources@cambridge |
| retrieve citation metadata in EndNote format |
This item has been accessed 246 times.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.