Measurement of the penetration depth and coherence length of MgB2 in all directions using transmission electron microscopy
Type
Change log
Authors
Abstract
We demonstrate that images of flux vortices in a superconductor taken with a
transmission electron microscope can be used to measure the penetration depth
and coherence length in all directions at the same temperature and magnetic
field. This is particularly useful for MgB
Description
Keywords
Journal Title
Conference Name
Journal ISSN
1550-235X