Title: Saliva samples are a viable alternative to blood samples as a source of DNA for high throughput genotyping
Authors: Abraham, Jean E
Maranian, Mel J
Spiteri, Inmaculada
Russell, Roslin
Ingle, Susan
Luccarini, Craig
Earl, Helena M
Pharoah, Paul PD
Dunning, Alison M
Caldas, Carlos
Issue Date: 30-May-2012
Abstract: Abstract Background The increasing trend for incorporation of biological sample collection within clinical trials requires sample collection procedures which are convenient and acceptable for both patients and clinicians. This study investigated the feasibility of using saliva-extracted DNA in comparison to blood-derived DNA, across two genotyping platforms: Applied Biosystems TaqmanTM and Illumina BeadchipTM genome-wide arrays. Method Patients were recruited from the Pharmacogenetics of Breast Cancer Chemotherapy (PGSNPS) study. Paired blood and saliva samples were collected from 79 study participants. The Oragene DNA Self-Collection kit (DNAgenotek®) was used to collect and extract DNA from saliva. DNA from EDTA blood samples (median volume 8 ml) was extracted by Gen-Probe, Livingstone, UK. DNA yields, standard measures of DNA quality, genotype call rates and genotype concordance between paired, duplicated samples were assessed. Results Total DNA yields were lower from saliva (mean 24 μg, range 0.2–52 μg) than from blood (mean 210 μg, range 58–577 μg) and a 2-fold difference remained after adjusting for the volume of biological material collected. Protein contamination and DNA fragmentation measures were greater in saliva DNA. 78/79 saliva samples yielded sufficient DNA for use on Illumina Beadchip arrays and using Taqman assays. Four samples were randomly selected for genotyping in duplicate on the Illumina Beadchip arrays. All samples were genotyped using Taqman assays. DNA quality, as assessed by genotype call rates and genotype concordance between matched pairs of DNA was high (>97%) for each measure in both blood and saliva-derived DNA. Conclusion We conclude that DNA from saliva and blood samples is comparable when genotyping using either Taqman assays or genome-wide chip arrays. Saliva sampling has the potential to increase participant recruitment within clinical trials, as well as reducing the resources and organisation required for multicentre sample collection.
URI: http://www.dspace.cam.ac.uk/handle/1810/243940
Other Identifiers: http://dx.doi.org/10.1186/1755-8794-5-19
Appears in Collections:BioMed Storage Collection

Files in This Item:

File Description SizeFormat
1755-8794-5-19.xml54.31 kBXMLView/Open
1755-8794-5-19.pdf1.28 MBAdobe PDFThumbnail
View/Open
1755-8794-5-19-S1.DOC137.5 kBMicrosoft WordView/Open
Additional resources for this item
retrieve citation metadata in EndNote format

This item has been accessed 194 times.

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.